Function description
Ascom IP-DECT System
8
3.4 Priorities in the IMS
Messages are distributed first-hand in priority order and secondly, for messages with same
priority, in time order. If distribution of a message fails it returns to the queue but is now
the last in time order. A message can be sent three times.
The different priority levels have reserved places of the max. 10 places for active messages.
Alarm has 2, high priority has 3, and normal priority has 5 reserved places. But, Alarm is
allowed to use all ten places and high priority is allowed to use the five places used for
normal priority.
3.5 Capacity
Alarm Messages from Cordless Handset
Time until received in the Unite system: ~ 2 sec
Incoming Messages to Cordless Handset 9d24 (version 3.0 or later)
The time for a message to be delivered differ dependent on how many characters the
message contain and if it is delivered to a single handset or a group of handsets.
Number of message characters:
No of Cordless
Handsets:
Time in seconds until one
handset is paged:
20 characters 1 ~ 3
120 characters 1 ~ 3
240 characters 1 ~ 4
500 characters 1 ~ 7
Number of message characters:
No of Cordless
Handsets:
Time in seconds until all
handsets are paged:
20 characters 1
10
30
100
~ 3
~ 4
~ 11
~ 32
120 characters 1
10
30
100
~ 3
~ 4
~ 13
~ 39